In the year 2006 our company was inaugurated as a leading importer and supplier of Automatic Detection Hardness Tester(HMV G20 Series). The offered tester is manufactured by making use of quality checked materials and advanced technology. It is used for testing the hardness of materials like plastic, rubber, steel etc. Furthermore, our esteemed clients can avail this Automatic Detection Hardness Tester(HMV G20 Series) from us at affordable prices in numerous technical specifications.
Features:
- Optimum performance
- Less maintenance
- Easy to operate
| Automatic Detection Type | Automatic Measurement Type (with Electric stage) | Manual Measurement Type | ||||||||||
Model | HMV - G21S | HMV - G21ST | HMV - G21D | HMV - G21DT | HMV - G-XY-S | HMV - G-XY-D | HMV - G-FA-S | HMV - G-FA-D | HMV - G20S | HMV - G20ST | HMV - G20D | HMV - G20DT | |
Operation Method | Via PC | Stand alone | |||||||||||
Maximum Number of Indenters Attached | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | |||||
Standard Indenters Provided | Vickers indenter | Vickers indenter | Vickers indenter | Vickers indenter | Vickers indenter | Vickers indenter | Vickers indenter | Vickers indenter | |||||
Maximum Number of Objective Lenses Attached | 2 | 4 | 2 | 4 | 2 | 4 | 2 | 4 | |||||
Standard Objective Lenses Provided | 40x | 40x 10x | 40x | 40x 10x | 40x extra-long working distance type 5x | 40x | 40x 10x | ||||||
Electric Turret Function | No | Yes | No | Yes | Yes | Yes | No | Yes | No | Yes | |||
Test Force | Nine force types: 98.07 mN, 245.2 mN, 490.3 mN, 980.7 mN, 1.961 N, 2.942 N,4.903 N, 9.807 N, and 19.61 N (HV0.01, 0.025, 0.05, 0.1, 0.2, 0.3, 0.5, 1, and 2), and 4 arbitrary settings (When low test force option is applied) Three types*3 in addition to the above: 9.807 mN, 19.61 mN, and 49.04 mN (HV0.001, HV0.002, and HV0.005) | ||||||||||||
Test Force Accuracy | Test force 9.807 mN to 1.951 N range: 1.5 % max.; Test force 1.961 N to 19.61 N range: +1 % max. | ||||||||||||
Loading Unit | Automatic loading and automatic force changing | ||||||||||||
Test Force Duration Time | 0 to 999 secs. 4 Selectable in second units. | ||||||||||||
Indentation Reading Method | Automatic reading from analysis of a digital image from the built-in CCD camera, or by manually setting the length lines in the PC window display. | Manual reading with an optical microscope | |||||||||||
Eyepiece | Image capture by the built-in CCD camera | Image capture by the built-in CCD camera With autofocus function | 10x | ||||||||||
Effective Measurement Range | 120 m x 90 m (with 40x objective lens) | 250 m x 250 m (with 40x objective lens) | |||||||||||
Indentation Measurement Resolution | 0.09 m (automatic), 0.18 m (manual) (with 40x objective lens) | 0.01 m (with 40x objective lens) | |||||||||||
XY Stage | Manual type Area: 100 mm x 100 mm; stroke: +12.5 mm; sample: max. height of 100 mm. Instrument lateral direction (width direction): unlimited*5; instrument depth direction: for sample width of 120 mm or less, unlimited*5; for sample width of 120 mm or more: 200 mm max.*5 Z axis stroke: 60 mm; spacers provided: 40 mm thick | Electric type Area: 125 mm x 125 mm; stroke: + 25 mm; sample: max. height of 65 mm. Instrument lateral direction (width direction): unlimited*5 Instrument depth direction: for sample width of 120 mm or less, unlimited*5; for sample width of 120 mm or more, 200 mm max.*5 Z axis stroke: 45 mm; spacers provided: 30 mm thick | Manual type Area: 100 mm x 100 mm; stroke: +12.5 mm; sample: max. height of 100 mm. Instrument lateral direction (width direction): unlimited*5; instrument depth direction: for sample width of 120 mm or less, unlimited*5; for sample width of 120 mm or more: 200 mm max.*5 Z axis stroke: 60 mm; spacers provided: 40 mm thick | ||||||||||
Data Processing Functions | Measurement modes: 1) Vickers hardness HV, 2) Knoop hardness HK*6, 3) Brinell hardness HB*6, 4) triangle pyramid hardness HT*6, 5) direct length reading L (m), 6) fracture toughness Kc | ||||||||||||
Statistical Calculation | Maximum number of data points | 5000 | 999 | ||||||||||
Statistical items | Average, standard deviation, coefficient of variation, maximum value, minimum value, conversion value (HK, HBW, HS, MPa, HRA, HRB.HRC, HRD, HR15N, HR30N, HR45N) | ||||||||||||
Graphical display | Variance, depth of hardening, transition graph | Variance, depth of hardening, transition graph | Variance graph, depth of hardening graph, histogram | ||||||||||
Results Display | Displayed items | Data No., diagonal line length, hardness, conversion value, average, standard deviation, coefficient of variation, maximum value, minimum value, pass/fail determination | |||||||||||
Graphical display | Variance graph, depth of hardening graph | Variance graph, depth of hardening graph | Variance graph, depth of hardening graph, histogram | ||||||||||
External Output | USB | Communication with PC (CCD camera: 1 port; instrument control: 1 port) | Transfer of test results to USB memory stick (CSV format) | ||||||||||
Printers | Dot printer, thermal printer, laser printer compatible | ||||||||||||
External Dimensions | Approx. W350 mm x D570 mm - H540 mm | ||||||||||||
Weight | Approx. 44 kg | Approx. 48 kg | Approx. 44 kg | ||||||||||
Power Requirements | Main body : Single phase AC 100-115 V, 1 A AC230 V, 0.5 A Provide a grounding wire. (Grounding resistance 100 max.) | Main body : Single phase AC 100-115 V, 1 A AC230 V, 0.5 A Motor Control box : Single phase AC100-115 V, 1 A AC230 V, 0.5 A (only HMV-G-FA/ -XY) Provide a grounding wire. (Grounding resistance 100 max.) | Main body : Single phase AC 100-115 V, 1 A AC230 V, 0.5 A Provide a grounding wire. (Grounding resistance 100 max.) | ||||||||||
Operating conditions | Temperature : 10 to 35oC (The temperature change under test is less then 1oC) Humidity : 60% max. (with no condensation) | ||||||||||||
Compatible PC | OS: Windows 7 (32-bit version)*9, CPU (IntelCoreTM2Duo or faster recommended), two USB2.0 ports used |
Plot No -49, Sector 8, IMT Manesar . Gurugram Haryana India +918037301335
Phone :+918037301335